IH153 ES - INFRA RED EMBER DETECTOR
Infra Red Ember Detector with Sensitivity Selection suitable for coal conveyor
Protection. Flickering LED Indication for normal operation 24 V DC, 4 wire
system with IHMB01XY base
Applications: Coal Conveyors, Material Conveyors where fire initially starts with the Ember. |
Early Detection Fire Alarm System for Coal Conveyor Protection
Data Sheet
Catalogue
IH163/1-4 NI* - SPARK DETECTOR ASSEMBLY
Spark detector assembly using 4Nos. Of four IR detector module (* denotes dia of duct)
Applications: Pneumatic ducts, Blow Room machinery ducts, Carding and Filter machineries duct, Paper and Wood industries dust ducts. |
Early Detection Fire Alarm System for Pneumatic Ducts
Data Sheet
Catalogue
IH042 SERIES PROBE TYPE HEAT DETECTOR
Probe type heat detector with M.S / S.S junction box suitable for Non-Explosion atmosphere application ( 50-230 Deg.C Temperature Setting)
- Probe Available in Aluminium / SS Materials also
Applications: Diesel Engine Room, Engine Test Bed, Paint Storage, Printing Machineries/Inside machineries/Generators. |
Protect Equipment /Machinery area with resettable heat detector by selecting suitable temperature range
Data Sheet
BIH302
Pilot CO2 Cylinder 6.8 litres water capacity Filled with 4.5kg CO2 Gas with 24v DC Solenoid operated cylinder valve with manual lever to operate Slave Cylinder valves / one No. Directional valve pneumatic actuator.
BIH302-E
Pilot CO2 Cylinder 6.8 litres water capacity Filled with 4.5kg CO2 Gas with 24v DC Explosion proof solenoid operated cylinder valve with manual lever to operate Slave Cylinder valves / one No. Directional valve pneumatic actuator. Hazardous Area Classification - CL-I, DIV-I, GRP-A,B,C & D. CL - II, DIV - I, GR - E
BIH302-N2-LP
Pilot N2 Cylinder 6.8 litres water capacity Filled with 1m3 N2 Gas at
150 bar Pressure fitted with 24v DC Solenoid cylinder valve with Pressure Gauge and Manual Lever to Operate Slave Cylinder valves / one No. Directional valve pneumatic actuator.
Data Sheet
BIH001-22.5/34-DT46/Z2 D1 AC MR
Detection & Control Unit with CO2 Extinguishing Cylinder Assembly
CO2 Kit for Machinery Protection
Data Sheet
IH015-*
NB CO2 Directional valve with pneumatic actuator & Limit Switch (* - 20/25/32/40/50NB)
Data Sheet
IH237- *
NB Manual Lock-out Valves with supervisory Limit Switch (* - 20/25/32/40/50NB)
Data Sheet
IH006R
Online Monitor - Mechanical
Indicator Type
Data Sheet
IH701 & IH706 Series
balawa 100/541 Inert Gas Cylinder Bank Frame Assembly using Master and Slave Cylinders principle using 80ltr W/C Inert cylinder with 200 bar pressure
MODEL SELECTION:
- Water Capacity of Cylinder ( 50/67/80 ltrs )
- Number of Cylinder ( 2 , 3 , …XX )
- SR for Single row and DR for Dual row DD - Filling Pressure ( 150/200/300 bar )
Data Sheet
IH045M
Conventional Microprocessor Based *Zone Fire Alarm Panel with inbuilt charger
IH045M-CS
Conventional Microprocessor Based *Zone Fire Alarm Panel with inbuilt charger. 2 Zone to 120 Zones As per Customer Specification / Requirement.
Data Sheet
IH046
IH046 MR AC Z2/D1
Conventional Microprocessor Based 2 Zone Fire Alarm Panel with Single gas discharge module with inbuilt charger and without battery
IH046 MR AC Z4/D1
Conventional Microprocessor Based 4 Zone Fire Alarm Panel with Single gas discharge module with inbuilt charger and without battery
IH046 MR AC Z4/D2
Conventional Microprocessor Based 4 Zone Fire Alarm Panel with two gas discharge module with inbuilt charger and without battery
Data Sheet
IH039B
IH039B
Manual Call Point - Press to Break type with Indoor application
IH039B- ADD-N
Addressable manual call point Break glass type for indoor application
Data Sheet
IH029
IH029
Manual Gas Discharge Station
IH029 - AD
Manual gas discharge station with inbuilt addressable module for indoor application
Data Sheet
IH028
IH028
Inhibit Switch / Abort Switch Suitable for indoor application
IH028 - AD
Inhibit Switch with inbuilt addressable module for indoor application
Data Sheet
IH147
Electronic Dual Tone
Hooter with Flashing Lamp for Indoor Application.
Data Sheet
IH601/DD-CO2/* (* - 4/9 kgs)
Defao series.. Fire DeTec Tube and CO2/ FM200 Extinguishing system
DD – Detect & Discharge Directly
Data Sheet
Catalogue
IH401 Series…
IH401 Series… TUBULAR TYPE FRAME ASSEMBLY
Model: AA-BB-CC-DD
IH401-bala-wa Fixed High Pressure Master Slave operation principle 45 Kg CO2 Cylinder Bank Assembly – TUBULAR FRAME & SINGLE ROW
(2 Nos of CO2 cylinders to 150 nos of CO2 cylinders)
MODEL SELECTION:
AA - CYLINDER CAPACITY - 45/22.5/33
BB - NO. OF CYLINDER - ( 2 to 24 nos.)
CC - SR for Single row and DR for Dual row
DD - EW for Electronic Weighing unit and MW for Mechanical weighing unit
Eg: 45/03/SR/EW
Data Sheet
IH174-Y*
Fire Diversion Dampers fitted with 24 V DC Solenoid valve & Pneumatic Actuator with Reducers and Match Rings ( * suitable to fix in 200 - 600mm Dia Ducts)
Data Sheet
IH8228 - Flameproof Triple Sensor UV-IR Flame Detector
LPCB Approved and CE Marked Flameproof Triple Sensor UV-IR Flame Detector with ATEX/PESO approved Flame Proof Enclosure. Flickering LED Indication for normal operation. 24 V DC, 4 wire system.
Applications: Chemical Areas, Petro- chemicalareas, PaintBooths/Paintshop Areas, Natural Gas installations, High ceiling/Open spaced buildings such as warehouse/Aircraft hangers. |
Early Detection Fire Alarm System for Hazardous area application
Data Sheet
Catalogue
IH765 Series.. ELECTRO CHEMICAL TYPE GAS DETECTORS
ELECTRO CHEMICAL TYPE Gas Detectors and M.S Junction box with Mounting Kit
Data Sheet
IH226 - UV-IR Flame Detector
Flickering LED, 24v DC, 4 Wire System with Mounting Base.
LPCB Approved & CE Marked
Applications: Fire pump house/Diesel Generator Room, Machinery production line, Storage area, Atriums/High Roof Areas/Warehouses, Paint/ Fuel Storage areas, Outdoor/Semi outdoor areas, Escalator areas, Car Parking, Under ground cellars |
Early Detection Fire Alarm System for Indoor/ Semi Outdoor/Suitable for all Non-Hazardous area application
Data Sheet
Catalogue
IH163/6 - IR SPARK DETECTOR MODULE
4 IR Spark Detector Module. Flickering LED Indication for normal operation. 24 V DC, 4 wire system.
Applications: Pneumatic ducts, Blow Room machinery ducts, Carding and Filter machineries duct, Paper and Wood industries dust ducts. |
Early Detection Fire Alarm System for Pneumatic Ducts
Data Sheet
Catalogue
IH042EI-AX
Sealed Probe type heat detector with indiacation & with ATEX approved explosion proof enclosure. ( 50-85 Deg.C Temperature Setting)
- Probe Available in Aluminium / SS Materials also.
Applications: Chemical or Flammable Liquid pumping & Transporting area, LPG filling yard / Pumping Station/Paint Booth, Gas Turbine / Other Machinery. |
Protect Equipment /Machinery area with resettable heat detector suitable for Ex.proof area application
Data Sheet
Catalogue
IH015-*E
NB CO2 Directional valve with pneumatic actuator & Flame Proof Limit Switch and Matching flange (* - 20/25/32/40/50NB)
Data Sheet
IH237-* E
NB Manual Lock-out Valves with supervisory Explosion proof Limit Switch (* - 20/25/32/40/50NB)
Data Sheet
IH701-CT & IH706 –CT Series
balawa 100/541 Inert Gas Cylinder Bank Cabinet type enclosure Assembly using Master and Slave Cylinders principle using 80ltr W/C Inert cylinder with 200 bar pressure
MODEL SELECTION:
- Water Capacity of Cylinder ( 50/67/80 ltrs )
- Number of Cylinder ( 2 , 3 , …XX )
- SR for Single row and DR for Dual row DD - Filling Pressure ( 150/200/300 bar )
Data Sheet
IH046M-CS
Conventional Microprocessor Type Fire Alarm Panel with gas discharge module as per Customer Specification / Requirement.
Features :
Zone – Detection
Various input multiple out logic
Discharge output
NO & NC Contacts Inbuilt Charger
Battery Backup
Data Sheet
IH039/1W
IH039/1W
Manual Call Point - Break Glass Type with hammer for indoor & Semi outdoor application
IH039/1W AD
Addressable manual call point for indoor and outdoor application
Data Sheet
IH029/1
IH029/1
Manual Gas Discharge Station for indoor & Semi outdoor application
IH029/1 AD/N
Manual gas discharge station with inbuilt addressable module for outdoor application
Data Sheet
IH028-1
IH028-1
Inhibit Switch / Abort Switch Suitable for indoor & Semi outdoor application
IH028/1 AD/ N
CO2 Inhibit Switch for outdoor application with inbuilt addressable module.
Data Sheet
IH147/1
Electronic Dual Tone Hooter with Flashing Lamp - for indoor & Semi outdoor application.
Data Sheet
IH604/DD - FK5112 - *kg (*-4/5 kgs)
Defao series.. Fire DeTec Tube and FK-5112 Extinguishing system
DA – Detect & Actuates
Data Sheet
IH401-CT Series…
IH401-CT Series… CABINET TYPE ENCLOSURE ASSEMBLY
Model: AA-BB-CC-DD
IH401-bala-wa Fixed High Pressure Master Slave operation principle 45 Kg CO2 Cylinder Bank Assembly – CABINET TYPE ENCLOSURE & SINGLE ROW
(2 Nos of CO2 cylinders to 150 nos of CO2 cylinders)
MODEL SELECTION:
AA - CYLINDER CAPACITY - 45/22.5/33
BB - NO. OF CYLINDER - ( 2 to 24 nos.)
CC - SR for Single row and DR for Dual row
DD - EW for Electronic Weighing unit and MW for
Mechanical weighing unit
Eg: 45/03/SR/EW
Data Sheet
IH006R-SS
SS Online Monitor - Mechanical Indicator Type
Data Sheet
IH153ES-P-IB - IR EMBER DETECTOR WITH INBUILT AIR PURGING UNIT
IR Ember Detector with inbuilt air purging unit with Sensitivity Selection suitable for coal conveyor Protection. Flickering LED Indication for normal operation 24 V DC, 4 wire system with IHMB01XY base.
Applications: Coal Conveyors, Material Conveyors where fire initially starts with the Ember. |
Early Detection Fire Alarm System for Coal Conveyor Protection
Data Sheet
Catalogue
IH838 Series.. ELECTRO CHEMICAL TYPE GAS DETECTORS
ELECTRO CHEMICAL TYPE GAS DETECTORS
- AMMONIA (NH3), CHLORINE (Cl), SULPHUR DIOXIDE (SO2), NITRIC OXIDE (NO), HYDROGEN SULPHIDE (H2S)
Data Sheet
IH 225R - Triple Sensor Flame Detector
Triple Sensor Flame Detector with High Sensitivity Selection and Air Purging Provision. Flickering LED, 24v DC, 4 Wire System with IHMB01XY base.
Applications: Fire pump house/Diesel Generator Room, Machinery production line, Storage area, Atriums/High Roof Areas/Warehouses, Paint/Fuel Storage areas, Outdoor/Semi outdoor areas, Escalator areas, Car Parking, Underground cellars. |
Early Detection Fire Alarm System for Indoor/Semi Outdoor/Suitable for all Non-Hazardous area application with high sensitivity selection
Data Sheet
Catalogue
IH153E S-P-AC-DC - IR EMBER DETECTOR WITH AIR PURGING UNIT
IR EMBER DETECTOR WITH AIR PURGING UNIT
Applications: Coal Conveyors, Material Conveyors where fire initially starts with the Ember. |
Early Detection Fire Alarm System for Coal Conveyor Protection
Data Sheet
Catalogue
IH042 VTC
Variable Temperature Probe Type Heat Detector with Temperature setting range from 0 deg C to 400 deg C
Applications: Diesel Engine Room, Acoustic Enclosure, Engine Test Bed. |
Use where temperature setting may needed to be changed as per site requirement
Data Sheet
BIH540/MV- 48/68
45kg CO2 Cylinder Assembly (Master) - Solenoid Operated
Data Sheet
IH007R NI
Online Monitor with Normal Indication Analogue LED Type
Data Sheet
BIH001/MV/PG/IG100/ IG541/200/48-80
80 Litre Water Capacity Inert Master Cylinder Assembly with Constant Pressure Reducer
Data Sheet
BIH046/ADD/N-CS
BIH046/ADD/N-CS
Fully integrated & Tested addressable Fire Detection and Extinguishing panel as per Customer Specification / Requirement.
BIH046/ADD/NOM-CS
Fully integrated & Tested addressable Fire
Detection and Extinguishing panel as per Customer Specification / Requirement with NOHMI protocol.
Features : Loops
Zone Groups
Various input multiple out logic
Discharge output
NO & NC Contacts
Inbuilt Charger
Battery Backup
Data Sheet
IH601/DA-CO2/* (* - 22.5/45KGS)
Defao series.. Fire DeTec Tube and CO2 / FM200 Extinguishing system
DA – Detect & Actuates
Data Sheet
Catalogue
IH039/1W AD
Addressable manual call point for indoor and outdoor application
Data Sheet
BIH004/SV-VT 48/68
45kg CO2 Cylinder Assembly (Slave) - Pneumatically Operated
Data Sheet
BIH001/SV/PG/IG100/ IG541/200/48-80
80 Litre Water Capacity Inert Slave Cylinder Assembly with Constant Pressure Reducer
Data Sheet
IH140H
IH140H
Electrical trip panel
IH140H-230V AC
Auxiliary Power Supply Panel
IH298
Deluge Control Panel
IH159/*
Annunciation Panel Denotes required no. of windows
IH140-ACP CS
Auxiliary Control Panel as per Customer Specification / Requirement
Data Sheet
IH604/DD - FK5112 - *kg (*-1/2/3/4/5 kgs)
Defao series.. Fire DeTec Tube and FK-5112 Extinguishing system
DD – Detect & Discharge Directly
Data Sheet
Catalogue
IH225R-VID - UV-IR Flame Detector with Visual Indication
UV-IR Flame Detector with Visual Indication.
Application: Remote location which is not accessed frequently, machinery production line, storage area, atriums, high roof areas, ware-houses, fire pump house, fuel storage areaas, outdoor and semi outdoor areas and underground cellars. |
Early Detection Fire Alarm System for Indoor/Semi Outdoor/Suitable for all Non-Hazardous area application.
Data Sheet
Catalogue
IH007-ST
Online Monitor Analogu Type with Normal Indication (Stand Alone)
Suitable for single cylinder.
Data Sheet
IH8153ES - FLAMEPROOF IR EMBER DETECTOR WITH AIR PURGING PROVISION
Infra Red Ember Detector with FM/ATEX approved Ex.Proof Enclosure with Air Purging Proviosion and Sensitivity Selection suitable for coal conveyor Protection. Flickering LED Indication for normal operation 24 V DC, 4 wire system with IHMB08XY base
Applications: Coal Conveyors, Coal bunkers, Material Conveyors where fire initially starts with the Ember |
Early Detection Fire Alarm System for Coal Conveyor Protection
Data Sheet
Catalogue
IH039B- ADD-N
Addressable manual call point Break glass type for indoor application
Data Sheet
IH8227 - TRIPLE SENSOR - UV & IR FLAME DETECTOR FOR FLAME PROOF AREA APPLICATION
TripleSensor-UV/IR Flame Detector with ATEX/ PESO approved Ex.ProofEnclosure. Flickering LED Indication for normal operation. 24VDC, 4 wire system with IHMB08XY base
Applications: Chemical Areas, Petro- chemicalareas, PaintBooths/Paintshop Areas, Natural Gas installations, High ceiling/Open spaced buildings such as warehouse/Aircraft hangers. |
Early Detection Fire Alarm System for Hazardous area application with sensitivity selection.
Data Sheet
Catalogue
IH148
Fixed Temperature Bi-Metal & Auto Reset type Heat Detector - 60 Deg.C Temperature setting with Dual LED indication suitable for wall or surface mounting type.
Applications: Machinery / Production area/Duct Application. |
Machinery / Area protection where smoke detectors are not suitable
Data Sheet
IH018-R
Non-Return Valve suitable for CO2 Master Cylinder
Data Sheet
BIH453
Constant Pressure Regulator.
Data Sheet
BIH345-AX
EX.PROOF FLASHERS - R (RED), Y(YELLOW) & B(BLUE)
Data Sheet
IH007R NI-4W
Online Monitor with Normal Indication - Analogue LED Type - 4 Wire Device.
(4 Wire system-2 wire for supply, 2 wire for Low Weight Signal)
Data Sheet
IH019
Non-Return Valve suitable for CO2 Slave Cylinder
Data Sheet
IH150
Response Indicator Dual LED
Data Sheet
IH1555 - TRIPLE IR FLAME DETECTOR
Triple IR Flame Detector. Flickering LED, 24v DC, 4 Wire System with IHMB01XY base
Applications: Diesel Day Tank Area, Open Car Parking area, Machinery Production Line, Storage area, High roof areas, Paint Storage areas, Fuel Storage areas, Outdoor or Semi Outdoor areas, Underground cellars, High fire risk machinery areas or installations, often coupled with an Automatic gas extinguishing system. |
Early Detection Fire Alarm System for Outdoor/Semi Outdoor/Suitable for all Non-Hazardous area application.
Data Sheet
Catalogue
IH009R
Online Monitor Control Panel - Single Area
(Suitable to connect upto 20 nos of Gas weight monitors)
Data Sheet
IH151 - Master Alarm Control Panel
This is a specially designed control panel operates that on 230V AC. Alternatively 24V DC input supply provision also available. Potential free ‘NO’ contact from pressure switch of cylinder or tube or any other signal initiating device is used in this panel to initiate fire indication and Dual Tone hooter sound.
Data Sheet
Catalogue
BIH004/2-NET-PG PS
40mm dia pressure gauge with switch.
Data Sheet
IH8555 - TRIPLE IR FLAME DETECTOR FOR FLAME PROOF AREA APPLICATION
Triple IR Flame Detector for Flame proof area application with ATEX & PESO approved Flame Proof Enclosure. Flickering LED indication for normal operation. 24 V DC, 4 wire system with mounting bracket.
Applications: Chemical Areas, Petro-chemical areas, Paint Booths/ Paint shop Areas, Natural Gas installations, High ceiling/Open spaced buildings such as warehouse/Air craft hangers |
Early Detection Fire Alarm System for Hazardous area application with sensitivity selection.
Data Sheet
Catalogue
IH009-2A
Continuous Gas Weight Monitor Control Panel suitable for 2 Area Application (Suitable to connect 40Nos.of Gas Weight Monitors) (Common for all type of Weight Monitor (Model No.CGWM-CP)
Data Sheet
IH166 - UV Flame Detector - (2 wire system)
UV Flame Detector 24 VDC–2 wire system suitable to connect Fire Alarm Panel with IHMB01XY base
Applications: UPS Room, Server Room, Cotton Go down, Indoor clean rooms |
Early Detection Fire Alarm System for Indoor and Clean Rooms where UV source is not available for Non-Hazardous area application
Data Sheet
Catalogue
IH324/*
Wintergreen Odorizers suitable for *Cylinder Bank Arrangement (* No.of Cylinders)
Data Sheet
IH006R P3
IH006R P3- Dia 80MM – COLLAR ASSEMBLY- ?80MM INCLUDING 1 PAIR HANGING ROD OF SIZE * (* - Hanging Rod size)
IH006R P4- Dia 95MM COLLAR ASSEMBLY - ? 95MM - INCLUDING 1 PAIR HANGING ROD OF SIZE * (* - Hanging Rod size)
Data Sheet
IH042 SERIES PROBE TYPE HEAT DETECTOR
Probe type heat detector with PESO & ATEX approved Junction Box ( 50-230 Deg.C Temperature Setting)
- Probe Available in Aluminium / SS Materials also
Applications: Diesel Engine Room, Engine Test Bed, Paint Storage, Printing Machineries/Inside machineries/Generators. |
Protect Equipment /Machinery area with resettable heat detector by selecting suitable temperature range
Data Sheet
IH012 & IH012-C
CO2 Nozzle with cone horn with IH014 Gas discharge Nozzle adaptor
*IH012-C - Dicharge Nozzle Conical Type with blow-off Cap
Data Sheet
IH006R P3/SP
SPLIT COLLAR ASSEMBLY - ? 80MM - INCLUDING 1 PAIR HANGING ROD OF SIZE *
(* - Hanging Rod size)
IH006R P4/SP SPLIT COLLAR ASSEMBLY - ? 95MM- INCLUDING 1 PAIR HANGING ROD OF SIZE * (* - Hanging Rod size)
Data Sheet
IH8221 - FLAME PROOF TRIPLE SENSOR UV-IR FLAME DETECTOR
Flickering LED, Resettable 24v DC with IHMB03-XY Mounting Base.
PESO Approved & ISI Marked
Applications:Chemical Areas,Petro-Chemical areas,PaintBooths/Paintshop Areas,Natural Gas Installations,High ceiling/open spaced buildings such as warehouse/Aircraft hangers.
|
Early Detection Fire Alarm System for Hazardous area application.
Data Sheet
Catalogue
IH042 DSS Series..
Probe type horizontal heat detector with junction box, Auto Resettable Bimetal Type Heat Detector ( 50-100 Deg.C Temperature Setting)
- Probe Available in Aluminium / SS Materials also
Applications: Diesel Engine Room, Engine Test Bed, Paint Storage, Printing Machineries/Inside machineries/Generators. |
Protect Equipment /Machinery area with resettable heat detector by selecting suitable temperature range
Data Sheet
IH167 - UV Flame Detector (4 wire system)
UV Flame Detector. Flickering LED Indication for Normal operation 24 V DC, 4 wire system with IHMB01XY base
Applications: UPS Room, Server Room, Cotton Go down, Indoor clean rooms |
Early Detection Fire Alarm System for Indoor and Clean Rooms where UV source is not available for Non-Hazardous area application
Data Sheet
Catalogue
IH011 Series
CO2 Nozzle with cone horn suitable to fit in the machinery also referred as CO2 DISCHARGE NOZZLE-SMALL TYPE
Data Sheet
IH006R P7-SP
IH006R P7- ?80MM – FLANGE TYPE COLLAR ASSEMBLY INCLUDING 1
PAIR HANGING ROD OF SIZE * (* - Hanging Rod size)
IH006R P6- ?80MM FLANGE TYPE COLLAR ASSEMBLY - ? 95MM INCLUDING 1 PAIR HANGING ROD OF SIZE * (* - Hanging Rod size) Hanging Rod Size – 195 / 275 / As per Customer Requirement
Data Sheet
IH475
3/4" Inert Nozzle suitable for fixed installation
Data Sheet
IH8166 - UV FLAME DETECTOR FOR FLAME PROOF AREA APPLICATION
UV Flame Detector with Ex. Proof Enclosure. Flickering LED Indication for normal operation. 24 V DC, 4 wire system.
Applications: Indoor clean rooms – Chemical production areas. |
Early Detection Fire Alarm System for Indoor and Clean Rooms where UV source is not available for Hazardous area application
Data Sheet
Catalogue
IH388
Safety Sign Board - Vacate Immediately
Data Sheet
IH388/1
Safety Sign Board - Do Not Enter
Data Sheet
IH225R-MC - Triple Sensor Flame Detector
Triple Sensor Flame Detector with High Sensitivity Selection. Flickering LED, 24v DC, 4 Wire System with IHMB01XY base
“IH225R-MC is a custom designed for flame detection in short range applications”
Applications:Machinery Areas / Printing Machineries. |
Early Detection Fire Alarm System for Indoor/Semi Outdoor/Suitable for all Non-Hazardous area application with high sensitivity selection
Data Sheet
Catalogue