Logo Logo
balawa Series - Product List
01 IH030-X /N / S / D / RF / CT / WOR / WOH CO2 CYLINDER FRAME ASSEMBLY WITH ONLINE MONITOR MOUNTING RAIL & ACCESSORIES

PART NO. SELECTION:

X - No. of 45kg CO2 Cylinders (1,2,3..xx)
N - Normal ( Includes rail assembly, header)
S - Single Row
D - Dual Row
WOR - Without Rail Assembly
WOH - Without Header
RF - Roof Type
CT - Cabinet Type Enclosure
Fully Pre-assembled integrated & tested Frame assembly for CO2 Gas Suppression System
  EXAMPLES:-
  1-1) Part No: IH030-5 / N / S
Description: CO2 Cylinder Frame Assembly suitable for 5 nos of 45 kg CO2 cylinder, single row with online monitoring Rail and Header
  1-2) Part No: IH030-5 / N / S / RF
Description: CO2 Cylinder Frame Assembly suitable for 5 nos of 45 kg CO2 cylinder, single row with online monitoring Rail and Header with Roof
  1-3) Part No: IH030-5 / N / S / CT
Description: CO2 Cylinder Frame Assembly suitable for 5 nos of 45 kg CO2 cylinder, single row with online monitoring Rail and Header with Cabinet type Enclosure
  1-4) Part No: IH030-5 / N / D
Description: CO2 Cylinder Frame Assembly suitable for 5 nos of 45 kg CO2 cylinder, Dual row with online monitoring Rail and Header
  1-5) Part No: IH030-5 / N / D / RF
Description: CO2 Cylinder Frame Assembly suitable for 5 nos of 45 kg CO2 cylinder, Dual row with online monitoring Rail and Header with Roof
  1-6) Part No: IH030-5 / N / D / CT
Description: CO2 Cylinder Frame Assembly suitable for 5 nos of 45 kg CO2 cylinder, Dual row with online monitoring Rail and Header with Cabinet type Enclosure
  1-7) Part No: IH030-5 / S/ WOR
Description : CO2 Cylinder Frame Assembly suitable for 5 nos of 45 kg CO2 cylinder, single row without online monitoring Rail and with Header
  1-8) Part No: IH030-5 / D/ WOR
Description : CO2 Cylinder Frame Assembly suitable for 5 nos of 45 kg CO2 cylinder, Dual row without online monitoring Rail and with Header
02   FULLY ASSEMBLED & TESTED CO2 CYLINDERS AND BANK ASSEMBLY  
  02-1) Part No: IH401 Series…
Description : IH401-bala-wa  Fixed High Pressure  Master Slave operation principle 45 Kg CO2 Cylinder Bank Assembly
(2 Nos of CO2 cylinders to 150 nos of CO2 cylinders)
CO2 Gas Suppression System using Master Slave Operation
  02-2) Part No: IH402 Series…
Description : IH402-bala-wa  Fixed High Pressure  N2 / CO2 Pilot and Slave Cylinders principle 45 Kg CO2 Cylinder Bank Assembly
(2 Nos of CO2 cylinders to 150 nos of CO2 cylinders)
CO2 Gas Suppression System using Pilot and Slave Operation
  02-3) Part No: IH403 Series…
Description : IH403-bala-wa  Fixed High Pressure Main & Standby,  Master Slave Operation principle 45 Kg CO2 Cylinder Bank Assembly
(2 Nos of CO2 cylinders to 150 nos of CO2 cylinders)
CO2 Gas Suppression System using Main & Standby, Master Slave Operation
  02-4) Part No: IH404 Series…
Description : IH404-bala-wa  Fixed High Pressure Main & Standby, Master Slave Operation principle using common bank with directional valves 45 Kg CO2 Cylinder Bank Assembly 
(2 Nos of CO2 cylinders to 150 nos of CO2 cylinders)
CO2 Gas Suppression System using Main & Standby, Master Slave with directional valves Operation
  02-5) Part No: IH405 Series…
Description : IH405-CS-bala-wa  Fixed High Pressure  45 Kg CO2 Cylinder Bank Assembly Fully Integrated & Tested As Per Customer Specification
(2 Nos of CO2 cylinders to 150 nos of CO2 cylinders)
CO2 Gas Suppression System as per customer specification
  02-6) Part No: IH406 Series…
Description : IH406-bala-wa  Fixed High Pressure  N2 / CO2 Pilot and Slave Cylinders, Main & Standby operation principle using 45 Kg CO2 Cylinder Bank Assembly
(2 Nos of CO2 cylinders to 150 nos of CO2 cylinders)
CO2 Gas Suppression System using Pilot and Slave, Main & Standby Operation
03   FULLY ASSEMBLED & TESTED INERT CYLINDERS AND BANK ASSEMBLY  
   
  03-1) Part No: IH702 Series…
Description : balawa 100 Inert Gas Cylinder Bank Assembly using Pilot and Slave Cylinders principle using 80ltr W/C Inert cylinder with 200 bar pressure 
balawa-100 inert gas suppression system using Pilot and Slave Operation
  03-2) Part No: IH706 Series…
Description : balawa 541 Inert Gas Cylinder Bank Assembly using Pilot and Slave Cylinders principle  using 80ltr W/C Inert cylinder with 200 bar pressure 
balawa-541 inert gas suppression system using Pilot and Slave Operation
  03-3) Part No: IH709 Series…
Description : balawa 55 Inert Gas Cylinder Bank Assembly using Pilot and Slave Cylinders principle  using 80ltr W/C Inert cylinder with 200 bar pressure 
balawa-55 inert gas suppression system using Pilot and Slave Operation
04 BIH001/MV- 48/68 45kg CO2 Cylinder Assembly (Master) - Solenoid Operated CO2 Gas Suppression System
05 BIH004/SV- 48/68 45kg CO2 Cylinder Assembly (Slave) - Pneumatically Operated  CO2 Gas Suppression System
06 BIH302 Pilot CO2 Cylinder 6.8 litres water capacity Filled with 4.5kg CO2 Gas with 24v  DC Solenoid operated cylinder valve with manual lever to operate Slave Cylinder valves / one No. Directional valve pneumatic actuator.  CO2 Gas Suppression System
07 BIH302-E Pilot CO2 Cylinder 6.8 litres water capacity Filled with 4.5kg CO2 Gas with 24v DC Explosion proof solenoid operated cylinder valve  with manual lever to operate Slave Cylinder valves / one No. Directional valve pneumatic actuator. Hazardous Area Classification - CL-I, DIV-I, GRP-A,B,C & D. CL - II, DIV - I, GR - E  CO2 Gas Suppression System
08 BIH302-N2 Pilot N2 Cylinder 6.8 litres water capacity Filled with 1m3 N2 Gas at 150 bar Pressure fitted with 24v DC Solenoid cylinder valve with Pressure Gauge and Manual Lever to Operate Slave Cylinder valves / one No. Directional valve pneumatic actuator.  CO2 / Inert Gas Suppression System
09 BIH001-22.5/34-DT-46/Z2 D1 AC MR Detection & Control Unit with CO2 Extinguishing Cylinder Assembly CO2 Kit for
Machinery Protection
10 BIH001-34-46/Z2/D1-AC MR-1 Detection & Control Unit with CO2 Extinguishing Cylinder Assembly CO2 Kit for
Machinery Protection
11 IH324/* Wintergreen Odorizers suitable for *Cylinder Bank Arrangement (* No.of Cylinders) CO2 Gas Suppression System
12 IH018 Non-Return Valve suitable for CO2 Master Cylinder CO2 Gas Suppression System
13 IH019 Non-Return Valve suitable for CO2 Slave Cylinder CO2 Gas Suppression System
14 IH015-* * NB CO2 Directional valve with pneumatic actuator & Limit Switch
(* - 20/25/32/40/50NB)
CO2 Gas Suppression System
14-1 IH015-*E * NB CO2 Directional valve with pneumatic actuator & Flame Proof Limit Switch and Matching flange         (* - 20/25/32/40/50NB) CO2 Gas Suppression System
15 IH237- * * NB Manual Lock-out Valves with supervisory Limit Switch
(* - 20/25/32/40/50NB)
CO2 Gas Suppression System
15-1 IH237-* E * NB Manual Lock-out Valves with supervisory Explosion proof Limit Switch          (* - 20/25/32/40/50NB) CO2 Gas Suppression System
16 IH012 CO2 Nozzle with cone horn  CO2 Gas Suppression System
17 IH014 Gas discharge Nozzle adaptor suitable for Part No. IH012  Accessories
18 IH011
Series…
CO2 Nozzle with cone horn sutiable to fit in the machinery  also refered as CO2 DISCHARGE NOZZLE-SMALL TYPE CO2 Gas Suppression System
19 IH475 3/4" Inert Nozzle suitable for fixed installation Inert Gas Suppression System
20 IH474 1/2" Inert Nozzle suitable for fixed installation Inert Gas Suppression System
21 IH138 Manifold Safety Valve  
22 IH213 Pneumatic Horn  
23 IH388 Safety Sign Board - Vacate Immediately  
24 IH388/1 Safety Sign Board - Do Not Enter CO2 Gas
Suppression System
25 IH006 R Online Monitor  - Mechanical Indicator Type
26 IH006E R Online Monitor  with explosion  proof limit switch  - Mechanical Indicator Type 
27 IH007R NI Online Monitor with Normal Indication - Analogue LED Type  
28 IH009 R Online Monitor Control Panel 
29 IH009R /2A Online Monitor Control Panel - 2 Area
30 IH039/1W Manual Call Point - Break Glass Type with hammer for indoor & Semi outdoor application
31 IH039/1W AD Addressable manual call point for indoor and outdoor application
32 IH039B Manual Call Point  - Press to  Break  type with Indoor application
33 IH039B- ADD-N Addressable manual call point Break glass type for indoor application
34 IH029 Manual Gas Discharge Station
35 IH029/H SI Manual Gas Discharge Station with Holding, Supervising & Indication.
36 IH029/1 Manual Gas Discharge Station for indoor & Semi outdoor application
37 IH029/1/H SI Manual Gas Discharge Station With Holding, Supervising & Indication.
38 IH029 - AD Manual gas discahrge station with inbuilt addressable module for indoor application CO2 Gas
Suppression System
39 IH029/1 AD /
N
Manual gas discahrge station with inbuilt addressable module for outdoor application
40 IH028 Inhibit Switch / Abort Switch Suitable for indoor Application
41 IH028-1 Inhibit Switch / Abort Switch Suitable for indoor & Semi outdoor application
42 IH028 - AD Inhibit Switch with inbuilt addressable module for indoor application
43 IH028/1 AD/
N
CO2 Inhibit Switch for outdoor application with inbuilt addressable module
44 IH147/2 Electronic Dual Tone Hooter with Flashing Lamp for Indoor Application. 
45 IH174-Y* Fire Diversion Dampers fitted with 24 V DC Solenoid valve & Pneumatic Actuator with Reducers and Match Rings suitable to fix in 200 - 350mm Dia Ducts Fire Diversion system for pneumatic ducts
46 IH174-Y-400-500 Fire Diversion Dampers fitted with 24 V DC  Solenoid valve & Pneumatic Actuator with Reducers and Match Rings suitable to fix in 400 - 500mm Dia Ducts Fire Diversion system for pneumatic ducts
47 IH171* Fire Stop Dampers fitted with 24 V DC Solenoid valve & Pneumatic Actuator with Reducers and Match Rings suitable to fix in 200 - 300mm Dia Ducts Fire Diversion system for pneumatic ducts
48 IH171/1 * Fire Stop Dampers suitable for square/rectangular duct of Size* (* - 300, 400, 500) Fire Diversion system for pneumatic ducts
49 IH801 eries.. IH801-IP Water mist pump skid for Intermediate Pressure fixed installation water mist system Water Mist System
50 IH801 eries.. IH801-IP Mist Nozzle for Intermediate Pressure fixed installation water mist system Water Mist System
51 IH901 eries.. IH901-HP Water mist pump skid for High pressure fixed installation water mist system Water Mist System
52 IH901 eries.. IH901-HP Mist Nozzle for High pressure fixed installation water mist system Water Mist System